UPS Bank 314 Ah
358.4 V · 314 Ah · floor cabinet
- 101.29 kWh usable at 90% depth of discharge
- EVE LF314 cells, Grade A, 112S1P
- In-house BMS 3-tier BMU/BCU · CAN, MODBUS_TCP
- 8,000 cycles at 80% DoD · 5-year warranty
The same 112S string on 314 Ah cells — three times the energy in roughly twice the footprint. For long-autonomy UPS rooms and DG offset.
5 years against manufacturing defect, and against usable capacity falling below 80% of rated within 8,000 cycles at 80% depth of discharge.
- Dispatch
- 45–60 days of a confirmed order
- Minimum order
- 1 unit
- Sold by
- UrjaPod
No payment is taken on this site. You get a proforma and UrjaPod's contact details; they confirm the order and raise the GST invoice.
Payment terms
Up to ₹2,00,000: full payment on order. Above that: 40% advance against proforma, 60% before dispatch, by NEFT or RTGS.
Technical specification
Electrical
| Nominal voltage | 358.4 V |
|---|---|
| Configuration | 112S1P |
| Nominal energy | 112.54 kWh |
| Usable energy | 101.29 kWh at 90% depth of discharge |
| Continuous discharge | 112 kW · 313 A |
| Maximum charge | 56 kW |
Cells and BMS
| Chemistry | LFP |
|---|---|
| Cell make | EVE LF314 |
| Cell grade | Grade A |
| Cell capacity | 314 Ah |
| BMS make | In-house 3-tier BMU/BCU |
| BMS comms | CAN, MODBUS_TCP |
Mechanical and environmental
| Enclosure | cabinet |
|---|---|
| Ingress rating | IP54 |
| Cooling | forced air |
| Dimensions | 1200 × 900 × 2100 mm |
| Weight | 980 kg net · 1060 kg gross |
Life, warranty and compliance
| Cycle life | 8,000 cycles at 80% DoD |
|---|---|
| Warranty | 5 years |
| Certifications on file | UN 38.3, IS 16046, MSDS |
| HSN code | 8507 |
| GST | 18% |
| Country of origin | India (assembled) · cells imported from China |
| Dangerous goods | UN3480 · Class 9 · 1,12,540 Wh — surface freight only |
Build sheet
What is actually inside the box, with the document that backs each claim. If a competing listing will not publish theirs, that is the comparison.
Warranty and terms
Set by UrjaPod, who warrants this pack and raises the invoice.
5 years against manufacturing defect, and against usable capacity falling below 80% of rated within 8,000 cycles at 80% depth of discharge.
- · Installation outside the manual, or by anyone other than a trained installer
- · Operation outside the stated temperature, voltage or current limits
- · Water ingress beyond the pack's IP rating
- · Physical damage, fire, flood or lightning
- · Any modification to the BMS, its firmware, or the pack wiring
- Minimum order
- 1
- Lead time
- 45–60 days
Up to ₹2,00,000: full payment on order. Above that: 40% advance against proforma, 60% before dispatch, by NEFT or RTGS.
Cancel before dispatch for a full refund. After delivery, a pack that arrives damaged, does not match its build sheet, or fails commissioning is replaced or refunded in full within 7 days.
- · Prices are ex-GST and valid for seven days from the date of the quotation.
- · Freight is surface only, as Class 9 dangerous goods, quoted by pincode zone.
- · Installation, civil work and any inverter or PCS are quoted separately.
- · Lead times run from receipt of a confirmed order and the advance.
Order from UrjaPod
Send the order request and you get a proforma and UrjaPod's direct phone, email and WhatsApp. They confirm, arrange freight and raise the GST invoice. No payment is taken on this site.